Panasonic Aquarea T-CAP R32 fault H63

Abnormal low pressure sensor

Heat pump

What it means

Abnormal low pressure sensor, occurring 4 times in 20 minutes

Likely causes

  1. Low pressure sensor defective or disconnected
  2. Insufficient refrigerant
  3. Clogged strainer or expansion valve

Where to start

  1. Check low pressure sensor wiring and continuity
  2. If low, check compressor efficiency, refrigerant charge, and strainer/expansion valve for blockage

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 164), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Panasonic manual for the Aquarea T-CAP R32. Check the model on the data plate before you order parts.