Panasonic Aquarea T-CAP R32 fault H28

Abnormal solar sensor

Heat pump

What it means

Indicates an abnormality detected in the solar sensor circuit, checked via connection and resistance against characteristic.

Likely causes

  1. Faulty connector connection
  2. Faulty indoor sub PCB
  3. Indoor communication error

Where to start

  1. Check solar temperature sensor wiring and continuity
  2. When H28 happens, check connection at CN207 - if not normal, correct sensor connection.
  3. If resistance matches characteristic, change Indoor sub PCB.

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 171), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Panasonic manual for the Aquarea T-CAP R32. Check the model on the data plate before you order parts.

Other Panasonic Aquarea T-CAP R32 fault codes