ECA Proteus fault F52
Immersion type NTC fault
Gas boilerFree account: 5 more checks, the readings and the manual page (page 61). No card needed.See the full F52 answer
What it means
Error code primarily relevant to the Immersion Type NTC sensor used for measuring water temperature in the tap water circuit. May indicate sensor failure causing hot water temperature inconsistency or boiler non-function.
Likely causes
- DHW temperature sensor cables not mounted
- Loose contact on sensor cable
- Damaged sensor cable
- Faulty DHW temperature sensor
- Faulty main board
- Faulty or damaged immersion type NTC sensor
- Damaged cable connections
- Rusting, corrosion, or deformation on the immersion probe
Where to start
- Check the DHW temperature sensor cables for mounting and loose contact
- If cables are fine, check DHW water temperature sensor for any problem via resistance check
- If sensor resistance is faulty, replace sensor
The full answer, free
- 5 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 61), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F52 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F50Storage tank sensor fault
- F51PT1000 solar sensor fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault