ECA Proteus fault E17
Related to plate heat exchanger / pump fault
Gas boilerFree account: 11 more checks, the readings and the manual page (page 59). No card needed.See the full E17 answer
What it means
Error code E17 is listed as a primary relevant error code associated with faulty operation of the plate heat exchanger and the pump.
Likely causes
- Return water temperature sensor not mounted or not working properly
- Main board may be broken
- Partial or full clogging of plate heat exchanger
- Overheating of central heating system due to internal by-pass failure
- Pump cable connection issues
- Pump not circulating water correctly
Where to start
- Check whether return water temperature sensor is mounted and sensor works properly. If not, replace CH return water temperature sensor
- (sensor is mounted and working properly), main board may be broken - replace main board
- Visual inspection for whether plate exchanger has a leak to outside
The full answer, free
- 11 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 59), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full E17 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F50Storage tank sensor fault
- F51PT1000 solar sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault