ECA Proteus fault E17

Related to plate heat exchanger / pump fault

Gas boiler
Free account: 11 more checks, the readings and the manual page (page 59). No card needed.See the full E17 answer

What it means

Error code E17 is listed as a primary relevant error code associated with faulty operation of the plate heat exchanger and the pump.

Likely causes

  1. Return water temperature sensor not mounted or not working properly
  2. Main board may be broken
  3. Partial or full clogging of plate heat exchanger
  4. Overheating of central heating system due to internal by-pass failure
  5. Pump cable connection issues
  6. Pump not circulating water correctly

Where to start

  1. Check whether return water temperature sensor is mounted and sensor works properly. If not, replace CH return water temperature sensor
  2. (sensor is mounted and working properly), main board may be broken - replace main board
  3. Visual inspection for whether plate exchanger has a leak to outside

The full answer, free

  • 11 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 59), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.