ECA Proteus fault F51

PT1000 solar sensor fault

Gas boiler
Free account: 2 more checks and the manual page (page 40). No card needed.See the full F51 answer

What it means

Fault relating to the PT1000 solar sensor. Requires confirming correct parameter setting for model type (P00=1 for HM model; P00: 2,4 used for HST model) before checking sensor wiring and resistance.

Likely causes

  1. Incorrect P00 parameter setting for model type
  2. PT1000 sensor cables not mounted
  3. Loose contact on sensor cable
  4. Damaged sensor cable
  5. Faulty PT1000 sensor
  6. Faulty main board

Where to start

  1. Ensure that P00=1 for HM model (P00: 2,4 is used for HST model)
  2. Check the PT1000 sensor cables for mounting and loose contact
  3. If cables are fine, check PT1000 sensor for any problem via resistance check