ECA Proteus fault F07
3 way shaft group / motorized valve related fault
Gas boilerFree account: 31 more checks, the readings and the manual page (page 69). No card needed.See the full F07 answer
What it means
Primary relevant error code associated with faulty operation of the 3-way shaft group, which controls switching between summer (DHW) and winter (CH) modes and provides internal by-pass function.
Likely causes
- Boiler remains only in central heating mode
- Radiators may get warm in summer mode due to valve fault
- Noise from motor during mode changes
- Wearing of valve causing heating problems
- No water in boiler / low pressure
- Faulty pressure sensor
- Faulty flue gas temperature sensor
- Loose or damaged pump cables
- Faulty pump
- Clogged central heating installation system
- Blocked flue gas side of heat exchanger or unsuitable coil gaps
- Faulty gas valve
- Faulty main board
- Damaged cable connections
- Rusting, corrosion, or deformation on the sensor probe
- Dirt or clogging on heat exchanger pipes
- Cracks or holes in exchanger pipes causing leakage
- Failure to meet heating demand
- Partial or full clogging of plate heat exchanger
- Overheating of central heating system due to internal by-pass failure
- Pump cable connection issues
- Pump not circulating water correctly
- 3-way motorized valve jammed causing boiler to remain in summer or winter mode
- Internal by-pass function not functional
- Water leakage at 3-way motorized valve connections
Where to start
- Check whether cable connections are proper and without damage
- Check whether connectors on the 3-way motor are installed properly
- Perform voltage testing for central heating and tap water modes
The full answer, free
- 31 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 69), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F07 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F50Storage tank sensor fault
- F51PT1000 solar sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault