ECA Proteus fault E21

Relevant to main board and gas valve faults

Gas boiler
Free account: 13 more checks, the readings and the manual page (page 56). No card needed.See the full E21 answer

What it means

Error code E21 is listed as a primary relevant error code associated with main board and gas valve faults.

Likely causes

  1. Main board ADC malfunction
  2. Main board failure
  3. Gas valve failure

Where to start

  1. Press 'Reset' button and observe if fault clears.
  2. If fault doesn't disappear after reset, replace main board.
  3. Visual inspection of main board cable connections and circuit board

The full answer, free

  • 13 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 56), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full E21 fix, readings and manual page. Free.See the full answer

From the ECA manual for the Proteus. Check the model on the data plate before you order parts.