ECA Proteus fault F47
Water pressure sensor fault
Gas boilerFree account: 6 more checks, the readings and the manual page (page 63). No card needed.See the full F47 answer
What it means
Error code relevant to the Water Pressure Sensor measuring water pressure in the central heating circuit. May indicate pressure sensing fault preventing detection of actual system pressure.
Likely causes
- Pressure sensor cables not mounted
- Loose contact on pressure sensor cables
- Faulty main board
- Faulty or damaged water pressure sensor
- Damaged cable connections
- Clogged water inlet of water pressure sensor
Where to start
- Check the pressure sensor cables for mounting and loose contact
- If cable is not mounted, mount it; if there is any damage, replace the cable
- If cables are fine, replace the pressure sensor
The full answer, free
- 6 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 63), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F47 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F50Storage tank sensor fault
- F51PT1000 solar sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault