ECA Proteus fault E15
Temperature sensors measurement deviation fault
Gas boilerFree account: the manual page (page 29). No card needed.See the full E15 answer
What it means
A deviation fault has been detected in the measurement comparison between temperature sensors, indicating either a sensor mounting/working problem or a main board fault.
Likely causes
- Temperature sensors not properly mounted or not working properly
- Main board may be broken
Where to start
- Check whether temperature sensors are mounted and sensors work properly. If YES (sensors are mounted and working properly), main board may be broken - replace main board; if NO (sensors not properly mounted/working), replace temperature sensors for CH supply and CH return waters.
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 29), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full E15 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F50Storage tank sensor fault
- F51PT1000 solar sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault