ECA Proteus fault F50
Storage tank sensor fault
Gas boilerFree account: 3 more checks and the manual page (page 39). No card needed.See the full F50 answer
What it means
Fault related to the storage tank (boiler) sensor, relevant when parameter P00=1 for HM model or P00: 3,4 for HST model. Diagnosis covers sensor cabling and sensor resistance check.
Likely causes
- Incorrect P00 parameter setting for model type
- Boiler sensor cables not mounted or loose contact
- Faulty sensor (resistance out of range)
- Faulty main board
Where to start
- Ensure that P00=1 for HM model (P00: 3,4 is used for HST model)
- Check boiler sensor cables for mounting and loose contact
- Fix cables if not mounted, replace if there is any damage
The full answer, free
- 3 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 39), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F50 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F51PT1000 solar sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault