ECA Proteus fault E01

Ignition/ionization electrode fault

Gas boiler
Free account: 23 more checks, the readings and the manual page (page 66). No card needed.See the full E01 answer

What it means

Primary relevant error code associated with faulty ignition or ionization electrode, affecting gas-air mixture ignition and flame detection in the burner.

Likely causes

  1. Burrs, dirt or debris at inlet/outlet ends or inside venturi
  2. Improper installation with gas pipe, fan, or silencer
  3. Improper burning emission values
  4. Noisy (whistling) operation
  5. Main board failure
  6. Gas valve failure causing improper gas regulation or no burn
  7. Main heat exchanger fault causing failure to meet heating demand or leakage
  8. No gas supply to boiler
  9. Incorrect gas settings
  10. Fan-Venturi-Silencer assembly incorrect
  11. Blocked condensate trap or incorrect condensate drain incline
  12. Ignition electrode cable latched incorrectly or loose contact
  13. Damaged or improper cable connections
  14. Oxidation on ignition electrode
  15. Electrode in contact with water
  16. Gas valve connector/resistance fault
  17. No ignition and burning as result of electrode end distance too much or too narrow
  18. Noisy burning (explosion burning) as result of late ignition
  19. Due to electrode being away from the burner, reduced ionization flow and flame loss in boiler time to time

Where to start

  1. Visual inspection: check for burrs, dirt, etc. at inlet and outlet ends and inside venturi
  2. Check installation of venturi with gas pipe, fan, and silencer
  3. Check burning emission values using a gas analysis boiler

The full answer, free

  • 23 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 66), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full E01 fix, readings and manual page. Free.See the full answer

From the ECA manual for the Proteus. Check the model on the data plate before you order parts.