Immergas Victrix fault 70

Return/flow probe exchange

Gas boiler

What it means

In case of an incorrect boiler wiring connection the error is detected.

Likely causes

  1. Incorrect boiler wiring connection (return/flow probes swapped)
  2. Flow and return probes reversed or incorrectly connected

Where to start

  1. Verify boiler wiring connections
  2. Check flow and return probe connections
  3. Check wiring connections of return and flow probes