Immergas Victrix fault 01
No ignition block
Gas boilerWhat it means
If room central heating or domestic hot water production is requested (when the boiler is paired with a storage tank unit), the boiler does not switch on within the preset time.
Likely causes
- Boiler fails to ignite within preset time on CH or DHW request
- Upon appliance commissioning or after extended downtime, it may be necessary to eliminate the block.
- Boiler fails to ignite within preset time on request
- Extended downtime prior to commissioning
- Ignition failure within preset time
- Dirty burner
- Clogged primary heat exchanger
- Incorrect combustion parameters
- Intake-exhaust terminal not correctly installed
- Normal behaviour following calibration - system still adjusting ignition parameters
- Normal behaviour after calibration - system still adjusting
- Post-calibration adjustment period of burner ignition
- Incorrect nozzle diameter for gas type
- Incorrect gas pressure setting
Where to start
- Check ignition sequence upon commissioning or after extended downtime
- Press the Reset button
- Check the indicated components (burner, primary heat exchanger, combustion parameters, intake-exhaust terminal)
The full answer, free
- 56 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 56), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Immergas manual for the Victrix. Check the model on the data plate before you order parts.
Other Immergas Victrix fault codes
- 02Safety thermostat function block (NTC flow/return overheating)
- 03Flue safety thermostat block
- 04Contacts resistance block / damaged hardware board
- 10Insufficient system pressure
- 15Configuration error
- 20Parasite flame block
- 24Push button control panel anomaly
- 29Flue probe anomaly
- 31Loss of remote control communication
- 38Loss of flame signal
- 43Block due to loss of flame signal
- 45ΔT high
- 47Burner power limitation
- 49High temperature block on return probe
- 60Anomaly pump blocked
- 61Air in circulator
- 70Return/flow probe exchange
- 75Return and/or flow probe malfunction
- 76Flow and/or return probes temperature drift
- DLSystem deaeration procedure
- E60Circulation pump alarm
- E61Circulation pump alarm
- FUFixed speed fan test
- MAManual activation of operating devices for verification