Immergas Victrix fault 61
Air in circulator
Gas boilerWhat it means
Air is detected inside the pump; the pump cannot work.
Likely causes
- Air trapped inside the pump/circulator
- Air in central heating circuit
- Low power supply voltage
- Rotor seized
- Electrical error in pump
- Lack of water in the appliance
- Little water circulation in the system
- Blocked pump
- Disconnected PWM signal wire (when boiler is requesting ignition but pump stays in stand-by)
- Disconnection of the PWM control signal between PCB and pump
- Boiler electronics not requesting pump ignition (normal, condition OK)
- Boiler electronics requesting pump ignition but pump not responding (faulty condition, probable disconnection of the PWM signal)
- Blocked pump (Par. 1.29)
- Drain trap not yet filled with condensate on first start-up, allowing combustion products to escape via condensate drain
- Long period of inactivity causing pump/rotor seizure
Where to start
- Vent the pump
- Vent the pump and the central heating circuit
- Check pump symbol 1 (red) status on the pump head
The full answer, free
- 42 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 58), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Immergas manual for the Victrix. Check the model on the data plate before you order parts.
Other Immergas Victrix fault codes
- 01No ignition block
- 02Safety thermostat function block (NTC flow/return overheating)
- 03Flue safety thermostat block
- 04Contacts resistance block / damaged hardware board
- 10Insufficient system pressure
- 15Configuration error
- 20Parasite flame block
- 24Push button control panel anomaly
- 29Flue probe anomaly
- 31Loss of remote control communication
- 38Loss of flame signal
- 43Block due to loss of flame signal
- 45ΔT high
- 47Burner power limitation
- 49High temperature block on return probe
- 60Anomaly pump blocked
- 70Return/flow probe exchange
- 75Return and/or flow probe malfunction
- 76Flow and/or return probes temperature drift
- DLSystem deaeration procedure
- E60Circulation pump alarm
- E61Circulation pump alarm
- FUFixed speed fan test
- MAManual activation of operating devices for verification