Ideal Logic Air fault 9.1.20
Configuration fault (controller code 146)
Heat pumpFree account: 1 more check, the readings and the manual page (page 75). No card needed.See the full 9.1.20 answer
What it means
The indoor unit configuration is wrong or incomplete, often because a sensor that the chosen system type needs is not connected. Manual chart 9.1.20 (page 75); code 146 on the controller fault list.
Likely causes
- Incorrect indoor unit configuration.
- Flow thermistor (indoor) not connected.
- Return thermistor not connected.
- Outside sensor not connected.
- DHW thermistor not connected (where fitted).
- Header thermistor not connected (where fitted, cascade only).
Where to start
- Read the fault history to confirm the code and when it occurred: Settings, user level Installer (password), Test function menu, Fault History (6800 History 1, 6801 Fault Code 1), page
- The last 10 faults can be scrolled through.
- Re-configure the indoor unit (Installer level, spanner menu, Quick Set Up, page 58) and check if the fault persists.
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 75), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full 9.1.20 fix, readings and manual page. Free.See the full answer
From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.
Other Ideal Logic Air fault codes
- 127Anti-legionella temperature fault
- 33Flow thermistor (indoor) fault
- 366Room temperature sensor fault
- 385Low mains voltage
- 490No outdoor connection
- 499No outdoor connection
- 516No outdoor connection
- 60Room stat 1 fault
- 7Number of heat pump starts exceeded
- 9.1.11LPB (cascade) address collision (controller code 82)
- 9.1.12BSB short circuit (controller code 83)
- 9.1.13BSB address collision (controller code 84)
- 9.1.142 clock time masters (controller code 100)
- 9.1.15Clock without back-up (controller code 102)
- 9.1.16Source temperature too low
- 9.1.177093 DHW setpoint fault (controller code 126)
- 9.1.18Anti-legionella temperature fault (controller code 127)
- 9.1.22Room temperature sensor fault (controller code 366)
- 9.1.24Low mains voltage (controller code 385)
- 9.1.25No cascade master (controller code 489)
- 9.1.26No outdoor connection (controller code 490, 499 and 516)
- 9.1.28Number of heat pump starts exceeded (controller code 7)
- 9.1.29No central heating but hot water works