Ideal Logic Air fault 9.1.13
BSB address collision (controller code 84)
Heat pumpFree account: the readings and the manual page (page 73). No card needed.See the full 9.1.13 answer
What it means
Two devices on the BSB bus have the same address, a conflict between the smart interface and the RVS21. Manual chart 9.1.13 (page 73); code 84 on the controller fault list.
Likely causes
- Smart interface address conflict.
- RVS21 address conflict.
Where to start
- Read the fault history to confirm the code and when it occurred: Settings, user level Installer (password), Test function menu, Fault History (6800 History 1, 6801 Fault Code 1), page
- The last 10 faults can be scrolled through.
- Check if a smart interface is attached.
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 73), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full 9.1.13 fix, readings and manual page. Free.See the full answer
From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.
Other Ideal Logic Air fault codes
- 127Anti-legionella temperature fault
- 33Flow thermistor (indoor) fault
- 366Room temperature sensor fault
- 385Low mains voltage
- 490No outdoor connection
- 499No outdoor connection
- 516No outdoor connection
- 60Room stat 1 fault
- 7Number of heat pump starts exceeded
- 9.1.11LPB (cascade) address collision (controller code 82)
- 9.1.12BSB short circuit (controller code 83)
- 9.1.142 clock time masters (controller code 100)
- 9.1.15Clock without back-up (controller code 102)
- 9.1.16Source temperature too low
- 9.1.177093 DHW setpoint fault (controller code 126)
- 9.1.18Anti-legionella temperature fault (controller code 127)
- 9.1.20Configuration fault (controller code 146)
- 9.1.22Room temperature sensor fault (controller code 366)
- 9.1.24Low mains voltage (controller code 385)
- 9.1.25No cascade master (controller code 489)
- 9.1.26No outdoor connection (controller code 490, 499 and 516)
- 9.1.28Number of heat pump starts exceeded (controller code 7)
- 9.1.29No central heating but hot water works