Ideal Logic Air fault 60

Room stat 1 fault

Heat pump
Free account: 1 more check, the readings and the manual page (page 103). No card needed.See the full 60 answer

What it means

The controller has a fault on the room thermostat for central heating zone 1. The manual's chart (page 70) checks the thermostat batteries, then its wireless range, then the thermostat and smart interface.

Likely causes

  1. Depleted batteries in the room thermostat.
  2. Poor wireless signal between the room thermostat and the indoor unit.
  3. Faulty room thermostat or smart interface.

Where to start

  1. Read the fault history to confirm the code and when it occurred: Settings, user level Installer (password), Test function menu, Fault History (6800 History 1, 6801 Fault Code 1), page
  2. The last 10 faults can be scrolled through.
  3. Replace the batteries in the room thermostat for central heating zone 1 and check if the fault persists.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 103), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 60 fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.