Baxi Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault H.03.54

Temporary flame loss / shutdown due to low power supply voltage

Gas boiler

What it means

Temporary fault combining flame loss detection with shutdown caused by power supply voltage dropping too low.

Likely causes

  1. Electrode problem
  2. Gas supply issue
  3. Flue gas exhaust pipe issue
  4. Low power supply voltage

Where to start

  1. Check the electrode electrical connections
  2. Check the condition of the electrode
  3. Check the gas inlet pressure

The full answer, free

  • 3 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 72), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.