Baxi Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault H.01.18

No water circulation (temporary)

Gas boiler

What it means

Temporary lack of water circulation detected, possibly due to pump, pressure, or sensor issues.

Likely causes

  1. Insufficient boiler/installation circulation
  2. Low installation pressure
  3. Faulty pump
  4. Faulty temperature sensors
  5. Poor sensor connection

Where to start

  1. Check the installation pressure
  2. Check the operation of the pump
  3. Check the boiler/installation circulation