Baxi Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault E.04.08

Maximum safe temperature value reached

Gas boiler

What it means

Permanent fault requiring reset, indicating the maximum safe temperature value has been reached, due to insufficient circulation or safety thermostat issue.

Likely causes

  1. Insufficient circulation
  2. Safety thermostat fault

Where to start

  1. Check the pressure in the installation
  2. Switch on the manual degassing function
  3. Check that the pump is working

The full answer, free

  • 3 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.

Other Baxi Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault codes