Baxi Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault H.01.08

Flow temperature increase in heating mode too quick (10 minute stoppage)

Gas boiler

What it means

The flow temperature rises too quickly in heating mode, causing a temporary 10-minute stoppage.

Likely causes

  1. Insufficient boiler/installation circulation
  2. Low installation pressure
  3. Dirty heat exchanger
  4. Faulty temperature sensors
  5. Poor sensor connection

Where to start

  1. Check the boiler/installation circulation
  2. Check the installation pressure
  3. Check the cleanliness of the exchanger

The full answer, free

  • 13 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 71), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.