Worcester Bosch Greenstar 8000 fault 815

Low loss header temp. sensor faulty

Gas boiler
Free account: the readings and the manual page (page 76). No card needed.See the full 815 answer

What it means

Warning (category W): the low loss header temperature sensor reads faulty. On this boiler the manual expects the low loss header setting to be OFF, so the menu being switched on by mistake is the first thing to check.

Likely causes

  1. Menu accidentally switched on.
  2. Moisture on the connectors.
  3. PCB fault.

Where to start

  1. Check the menu has not been accidentally switched on.
  2. Check for moisture on the connectors.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 76), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 815 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.