Worcester Bosch Greenstar 8000 fault 1037

Outside temp. sensor faulty - heating backup operation active

Gas boiler
Free account: 1 more check, the readings and the manual page (page 77). No card needed.See the full 1037 answer

What it means

Category W warning indicating the outside weather sensor is faulty, causing heating to run in backup operation mode.

Likely causes

  1. Weather compensation accidentally enabled in menu
  2. Faulty positioning of outside weather sensor
  3. Faulty sensor connections
  4. Faulty sensor resistance/continuity

Where to start

  1. Check the weather compensation is applicable and the menu has not been accidently switched on
  2. Check the positioning of the outside weather sensor
  3. Check the weather sensor connections on the control board

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.