Worcester Bosch Greenstar 8000 fault 228

Flame signal without flame present

Gas boiler
Free account: 3 more checks, the readings and the manual page (page 74). No card needed.See the full 228 answer

What it means

Locking fault (category V) indicating the control is detecting a flame signal when no flame is actually present (false flame signal).

Likely causes

  1. Faulty flame sense electrode or lead
  2. Poor earth tag connections on boiler or electrodes
  3. Siphon malfunction or water collecting in sump
  4. Faulty air/gas ratio control valve
  5. Faulty control unit/burner control unit

Where to start

  1. Check ceramic insulator is not damaged; twist and pull to ensure it is not broken (can cause spark to earth).
  2. Check the flame sense and the lead; replace if required.
  3. Check the earth tags on the boiler and on the electrodes.

The full answer, free

  • 3 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 228 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.