Worcester Bosch Greenstar 8000 fault 232
Boiler locked by external switching contact
Gas boilerFree account: 3 more checks, the readings and the manual page (page 75). No card needed.See the full 232 answer
What it means
The boiler is locked by an external switching contact, for example the safety contact on a condensate lifting pump or an external temperature monitor.
Likely causes
- Connection plug for the external switch contact not plugged into the PCB.
- No feedback voltage at the external safety contact on the condensate lifting pump, which blocks the boiler.
- Switching point of the external temperature monitor set too low.
- Connection cable to the external temperature monitor damaged.
- External temperature monitor defective.
Where to start
- Make sure nothing is plugged into the red I3 connection (the external cut-off switch is not used in the UK).
- Check the connection plug for the external switch contact is plugged into the PCB.
- Check the feedback voltage at the external safety contact on the condensate lifting pump.
The full answer, free
- 3 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 75), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full 232 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 8000 fault codes
- 1010No communication via EMS BUS connection
- 1021Cylinder charging or hot water temperature sensor faulty
- 1037Outside temp. sensor faulty - heating backup operation active
- 1065System pressure sensor faulty or not connected
- 1068Outside temp. sensor or lambda probe faulty
- 1076Heat exchanger temp sensor disconnected
- 2085Internal fault
- 214Fan shut down during safety time
- 224Maximal flue gas thermostat or heat exchanger maximal thermostat has activated
- 228Flame signal without flame present
- 229Flame failed during burner operation
- 234Gas valve electrical fault
- 238Boiler electronics faulty
- 244System fault boiler electronics / basic controller
- 245System fault boiler electronics / basic controller
- 249System fault boiler electronics / basic controller
- 250System fault boiler electronics / basic controller
- 251System fault boiler electronics / basic controller
- 252System fault boiler electronics / basic controller
- 253System fault boiler electronics / basic controller
- 254System fault boiler electronics / basic controller
- 257System fault boiler electronics / basic controller
- 258System fault boiler electronics / basic controller
- 259System fault boiler electronics / basic controller