Worcester Bosch Greenstar 8000 fault 1010
No communication via EMS BUS connection
Gas boilerFree account: 3 more checks, the readings and the manual page (page 76). No card needed.See the full 1010 answer
What it means
The display (HMI) and the PCB have lost communication over the EMS BUS; the manual links it to wiring, Key module connections or the bridging links.
Likely causes
- HMI plug not fitted correctly.
- Key connections wired incorrectly.
- Bridging links not set correctly.
- 230 V external wiring run alongside the BUS connections.
- Faulty board.
Where to start
- Check the HMI shows a display, then remove the HMI and test the voltage to it.
- Check the white HMI plug on the far right of the PCB (low voltage connection).
- If a Key is used, check the Key connections (black, white, red, green) are in the correct position on the PCB, next to the orange BUS connection leaving one space, and check the pins on the plug.
The full answer, free
- 3 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 76), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full 1010 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 8000 fault codes
- 1021Cylinder charging or hot water temperature sensor faulty
- 1037Outside temp. sensor faulty - heating backup operation active
- 1065System pressure sensor faulty or not connected
- 1068Outside temp. sensor or lambda probe faulty
- 1076Heat exchanger temp sensor disconnected
- 2085Internal fault
- 214Fan shut down during safety time
- 224Maximal flue gas thermostat or heat exchanger maximal thermostat has activated
- 228Flame signal without flame present
- 229Flame failed during burner operation
- 232Boiler locked by external switching contact
- 234Gas valve electrical fault
- 238Boiler electronics faulty
- 244System fault boiler electronics / basic controller
- 245System fault boiler electronics / basic controller
- 249System fault boiler electronics / basic controller
- 250System fault boiler electronics / basic controller
- 251System fault boiler electronics / basic controller
- 252System fault boiler electronics / basic controller
- 253System fault boiler electronics / basic controller
- 254System fault boiler electronics / basic controller
- 257System fault boiler electronics / basic controller
- 258System fault boiler electronics / basic controller
- 259System fault boiler electronics / basic controller