Worcester Bosch Greenstar 8000 fault 224

Maximal flue gas thermostat or heat exchanger maximal thermostat has activated

Gas boiler
Free account: 4 more checks, the readings and the manual page (page 74). No card needed.See the full 224 answer

What it means

Locking fault (category V): the safety temperature limiter has tripped and shut the boiler down.

Likely causes

  1. Lead disconnected from the safety temperature limiter.
  2. Faulty high limit safety temperature limiter or harness.
  3. Low system pressure.
  4. Air trapped in the system or boiler.
  5. Pump seized, not running or blocked.
  6. Blockage or restriction in the boiler or pipework restricting flow.

Where to start

  1. Check whether the lead is disconnected from the safety temperature limiter.
  2. Check the safety temperature limiter and its harness for continuity.
  3. Check the flow temperature to confirm the actual temperature; the limiter may have tripped at a lower temperature, pointing to a limiter fault.

The full answer, free

  • 4 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.