Worcester Bosch Greenstar 8000 fault 306

Flame signal after closing the fuel supply

Gas boiler
Free account: the readings and the manual page (page 76). No card needed.See the full 306 answer

What it means

Locking fault (category V): a flame signal is still seen after the gas valve has closed, which points to the valve passing gas.

Likely causes

  1. Gas supply pressure issue to the property or at the gas valve inlet.
  2. Gas valve passing (not sealing correctly).
  3. PCB fault.

Where to start

  1. Make sure the working pressure returns immediately to the standing pressure when the gas valve closes.
  2. Check the gas supply to the property and the inlet on the gas valve (check the drop on the inlet).
  3. Check the gas valve is not passing.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 76), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 306 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.