Worcester Bosch Greenstar 8000 fault 2963

The heat exchanger sensor or both supply and heat exchanger sensors are defective

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 78). No card needed.See the full 2963 answer

What it means

Blocking fault (category B): the heat exchanger sensor (primary thermistor), or both supply and heat exchanger sensors, read as defective. It restarts on its own once the cause is removed.

Likely causes

  1. System not filled correctly.
  2. Air locks in the system.
  3. Faulty primary thermistor or sensor plug connection.
  4. Incorrect sensor resistance.
  5. Harness continuity fault.

Where to start

  1. Check the flow through the appliance and that the system is filled.
  2. Check for air locks in the system and purge if required.
  3. Check the heat exchanger sensor (primary thermistor) and that its plug is connected.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 78), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2963 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.