Worcester Bosch Greenstar 8000 fault 2927

Boiler electr. system fault

Gas boiler
Free account: 32 more checks, the readings and the manual page (page 77). No card needed.See the full 2927 answer

What it means

Category V fault relating to gas valve electrical circuit; grouped with codes 2923-2926.

Likely causes

  1. Faulty gas valve coil resistance
  2. Harness continuity failure
  3. Gas valve or PCB fault
  4. CO2/O2 content out of specified tolerance at max or min rated output

Where to start

  1. Check the voltage to the gas valve
  2. Check the resistance of the gas valve coils
  3. Check the continuity of harness

The full answer, free

  • 32 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2927 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.