Vaillant Gas boiler fault F.84

Temperature difference fault at the flow and return temperature sensors

Gas boiler

What it means

Fault indicating an abnormal temperature difference reading between the flow and return temperature sensors, typically due to incorrect sensor installation.

Likely causes

  1. Flow NTC installed incorrectly
  2. Return NTC installed incorrectly
  3. Defective heating flow or return temperature sensor

Where to start

  1. Check that the flow NTC has been installed correctly.
  2. Check that the return NTC has been installed correctly.
  3. Pull out the heating flow (4) and return temperature sensor (3)

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 63), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the Gas boiler. Check the model on the data plate before you order parts.