Vaillant Gas boiler fault F.33

Air pressure switch fault

Gas boiler

What it means

A fault has been detected with the air pressure switch, often linked to flue blockage or excessive counter-pressure.

Likely causes

  1. Air/flue pipe blocked
  2. Defective air pressure switch
  3. Cable connections not plugged in/loose
  4. Fan defective
  5. PCB defective
  6. Excessive counter-pressure in the air/flue pipe

Where to start

  1. Check the entire air/flue pipe.
  2. Check the cable connections.
  3. Check that the fan works correctly.

The full answer, free

  • 2 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 62), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the Gas boiler. Check the model on the data plate before you order parts.