Vaillant Gas boiler fault F.24

Safety shutdown: temperature rise too fast

Gas boiler

What it means

Safety shutdown due to the flow temperature rising too quickly.

Likely causes

  1. Pump blocked
  2. Pump runs with insufficient output
  3. Non-return valve blocked
  4. Non-return valve installed incorrectly
  5. System pressure too low
  6. Defective pump

Where to start

  1. Check that the pump is working correctly.
  2. Check that the non-return valve is working correctly.
  3. Check the installation position of the non-return valve.

The full answer, free

  • 6 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 60), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the Gas boiler. Check the model on the data plate before you order parts.

Other Vaillant Gas boiler fault codes