Mitsubishi Ecodan fault L8
Heating operation error (code 3 - main circulation)
Heat pumpWhat it means
'3' is displayed in Request code 567 in Running information. Applicable in Heating/FS modes. L8 is displayed if all of the following occur: a) No change on THW1 and THW5 (under 1°C for 20 minutes from unit starts operation); b) No change on THW1 (under 1°C for 10 minutes from booster heater starts operation); c) THW1 - THW2 < -5°C (for 10 minutes continuously).
Likely causes
- Failed thermistor TH1A, TH2, THW1, THW2, THWB1, THW5, THWB2, TH1B, THW6, THW7, THW8, or THW9
- THW1 has become detached from its holder
- Booster heater fault
- THW1 or THW2 or THW5 fault
- FTC board failure
Where to start
- Observe error code screen on main remote controller showing Code, Unit (e.g. FTC), Address, and Tel No. of installer if previously entered
- To reset: press F4 button (Reset) on the main remote controller
- Then press F3 (Yes) to confirm reset of current error
The full answer, free
- 19 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 49), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Mitsubishi manual for the Ecodan. Check the model on the data plate before you order parts.
Other Mitsubishi Ecodan fault codes
- 1Main remote controller display is blank
- 10Temperature of DHW tank water dropped
- 12Water leakage
- 13Heating system does not reach the set temperature
- 14In 2-zone temperature control, only Zone2 does not reach the set temperature
- 15When a PUHZ-FRP outdoor unit is connected, DHW or heating operation cannot run
- 16When a PUHZ-FRP outdoor unit is connected and in heat recovery operation, the set...
- 19Water discharges from pressure relief valve (primary circuit)
- 2'please wait' remains displayed on main remote controller
- 20Water discharges from pressure relief valve (sanitary circuit)
- 23Noisy water circulation pump
- 25Mechanical noise heard coming from the cylinder unit
- 26Water circulation pump runs for a short time unexpectedly
- 3Main screen appears then disappears after pressing ON button
- 33L6 error (circulation water freeze protection error) occurs during DHW or LP mode...
- 34The energy monitor value seems not correct
- 4LED2 on FTC is off (FTC powered on independent source)
- 5LED2 on FTC is blinking
- 6LED4 on FTC is off
- 7No water at hot tap
- 8Cold water at tap
- 9Water heating takes longer
- E0Main remote controller communication failure (reception error)
- E1Main remote controller control board failure