Mitsubishi Ecodan fault 8
Cold water at tap
Heat pumpWhat it means
Water at the tap is cold instead of hot, with multiple possible causes ranging from hot water run-out and mode settings to heat pump, booster heater, immersion heater, and 3-way valve faults.
Likely causes
- Outdoor unit abnormal stop
- Hot water run out
- Prohibit, schedule timer or holiday mode selected
- Heat pump not working
- Booster heater cut-out tripped
- Earth leakage circuit breaker for booster heater breaker (ECB1) tripped
- Booster heater thermal cut-out tripped and cannot be reset using manual reset button
- Immersion heater cut-out tripped
- Immersion heater breaker (ECB2) tripped
- 3-way valve fault
- Immersion heater degradation causing earth leakage, triggering circuit breaker (heater always OFF)
- Water circulation pump wear leading to pump failure
Where to start
- Check for error code and contact number displayed alternately on remote controller
- Confirm DIP SW2-5 is ON to enable backup operation
- Ensure DHW mode is operating and wait for DHW tank to re-heat
The full answer, free
- 37 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 54), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Mitsubishi manual for the Ecodan. Check the model on the data plate before you order parts.
Other Mitsubishi Ecodan fault codes
- 1Main remote controller display is blank
- 10Temperature of DHW tank water dropped
- 12Water leakage
- 13Heating system does not reach the set temperature
- 14In 2-zone temperature control, only Zone2 does not reach the set temperature
- 15When a PUHZ-FRP outdoor unit is connected, DHW or heating operation cannot run
- 16When a PUHZ-FRP outdoor unit is connected and in heat recovery operation, the set...
- 19Water discharges from pressure relief valve (primary circuit)
- 2'please wait' remains displayed on main remote controller
- 20Water discharges from pressure relief valve (sanitary circuit)
- 23Noisy water circulation pump
- 25Mechanical noise heard coming from the cylinder unit
- 26Water circulation pump runs for a short time unexpectedly
- 3Main screen appears then disappears after pressing ON button
- 33L6 error (circulation water freeze protection error) occurs during DHW or LP mode...
- 34The energy monitor value seems not correct
- 4LED2 on FTC is off (FTC powered on independent source)
- 5LED2 on FTC is blinking
- 6LED4 on FTC is off
- 7No water at hot tap
- 9Water heating takes longer
- E0Main remote controller communication failure (reception error)
- E1Main remote controller control board failure
- E2Main remote controller control board failure