Mitsubishi Ecodan fault 10
Temperature of DHW tank water dropped
Heat pumpWhat it means
Water in the DHW tank reheats too frequently due to significant temperature drop, often caused by water leakage, loose insulation, 3-way valve failure, or incorrect water pump speed setting.
Likely causes
- Water leakage in the pipes that connect to the DHW tank
- Water pump (sanitary circuit) speed setting failure
Where to start
- Reoccurring problem with error code Displayed: Use table 10-4 'Self diagnosis and action' to identify fault and correct
- Reoccurring problem with error code Not Displayed: Use table 10-5 'Troubleshooting by inferior phenomena' to identify fault and correct
- Non reoccurring problem, error Logged: Check temporary causes of defects such as operation of safety devices on refrigerant/water circuit including compressor, poor wiring, electrical noise etc; re-check symptom and installation environment, refrigerant amount (split systems only), weather conditions at time of fault
The full answer, free
- 12 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 55), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Mitsubishi manual for the Ecodan. Check the model on the data plate before you order parts.
Other Mitsubishi Ecodan fault codes
- 1Main remote controller display is blank
- 12Water leakage
- 13Heating system does not reach the set temperature
- 14In 2-zone temperature control, only Zone2 does not reach the set temperature
- 15When a PUHZ-FRP outdoor unit is connected, DHW or heating operation cannot run
- 16When a PUHZ-FRP outdoor unit is connected and in heat recovery operation, the set...
- 19Water discharges from pressure relief valve (primary circuit)
- 2'please wait' remains displayed on main remote controller
- 20Water discharges from pressure relief valve (sanitary circuit)
- 23Noisy water circulation pump
- 25Mechanical noise heard coming from the cylinder unit
- 26Water circulation pump runs for a short time unexpectedly
- 3Main screen appears then disappears after pressing ON button
- 33L6 error (circulation water freeze protection error) occurs during DHW or LP mode...
- 34The energy monitor value seems not correct
- 4LED2 on FTC is off (FTC powered on independent source)
- 5LED2 on FTC is blinking
- 6LED4 on FTC is off
- 7No water at hot tap
- 8Cold water at tap
- 9Water heating takes longer
- E0Main remote controller communication failure (reception error)
- E1Main remote controller control board failure
- E2Main remote controller control board failure