Midea Heat pump fault J47

Module type mismatch (after module resistance tested)

Heat pump

What it means

Fan module type mismatch detected after module resistance testing.

Likely causes

  1. Damage to cables
  2. Excessive number of connections
  3. Terminals not made to original specification
  4. Damage to seals
  5. Incorrect fitting of glands

Where to start

  1. Inspect casing for alteration affecting protection level
  2. Check seals or sealing materials have not degraded and still prevent ingress of flammable atmospheres
  3. Check cabling for wear, corrosion, excessive pressure, vibration, sharp edges or adverse environmental effects, including ageing and vibration from compressors or fans

The full answer, free

  • The manual page for this fault (page 150), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Midea manual for the Heat pump. Check the model on the data plate before you order parts.