Midea Heat pump fault H6
DC fan motor protection
Heat pumpWhat it means
Protects the DC fan motors from strong winds and abnormal power supply conditions. Triggered when fan speed continues below 50rpm for more than 40S from set fan step>0, or fan speed is lower than 50rpm for 3S during normal operation.
Likely causes
- Fan speed less than 50rpm for more than 40S with set fan step>0
- Fan speed lower than 50rpm for 3S during normal operation
- Strong wind affecting fan rotation
- Abnormal power supply to fan motor
- Refrigerant leak from container or system
- Damage to cables
- Excessive number of connections
- Terminals not made to original specification
- Damage to seals
- Incorrect fitting of glands
Where to start
- Check fan speed against 50rpm threshold
- Check duration of low speed condition (40S or 3S depending on operating state)
- Check for obstructions or strong wind affecting fan
The full answer, free
- 10 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 29), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Midea manual for the Heat pump. Check the model on the data plate before you order parts.
Other Midea Heat pump fault codes
- BAT4 sensor out of operation range protection
- C2IBH (internal backup heater) related fault
- C7Over-high temperature protection for IPM module
- D0Oil return operation active
- E0Water flow failure
- E1Phase loss or phase reversal
- E5T3 outdoor unit heat exchanger bottom temperature sensor error
- E6T4 ambient temperature sensor error
- E8Water flow protection
- E9Th return-air temperature sensor error
- EALow discharge temperature protection
- ECT5_2 water tank temperature sensor error (reserved)
- F1Protection for DC bus undervoltage
- F75Protection for insufficient discharge overheating degree
- FC1TL outdoor unit heat exchanger outlet temperature sensor error
- H1Communication error between main control PCB and inverter PCB
- H2T2 plate heat exchanger outlet refrigerant temperature sensor error
- H3T2B plate heat exchanger inlet refrigerant temperature sensor error
- H4Repeated L1* protection (3 times in 60 mins)
- H5Ta room temperature sensor error
- H7Compressor voltage protection
- H8H-SEN high pressure sensor error
- H9Tw2 zone 2 water flow temperature sensor error
- HATw_out plate heat exchanger outlet water temperature sensor error