Ideal Logic System IE fault F17

Pump fault

Gas boiler

What it means

Boiler has detected a fault with the pump.

Likely causes

  1. Faulty pump wiring
  2. Faulty pump
  3. System not filled/vented
  4. Closed valves
  5. Excessive flow/return differential
  6. Pump not rotating freely
  7. Isolation valves closed
  8. Pump not operating
  9. Radiator valves closed
  10. System blockages
  11. Pump not operating (wiring fault or pump failure)
  12. System blockage restricting flow
  13. Thermistor fault requiring replacement
  14. Faulty or failed return thermistor requiring replacement

Where to start

  1. Check pump wiring
  2. Verify boiler and CH system filled with water
  3. Verify all isolation, system filter and radiator valves are open