Ideal Logic System IE fault F4

Control/no flow thermistor fault

Gas boiler

What it means

Fault detected with control or no-flow thermistor.

Likely causes

  1. Control thermistor fault
  2. No-flow thermistor fault

Where to start

  1. Refer to Section 4.8 for detailed fault finding procedure
  2. Unclip return thermistor from return pipe and withdraw from boiler.
  3. Disconnect electrical lead from thermistor.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 54), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Ideal manual for the Logic System IE. Check the model on the data plate before you order parts.