Ideal Logic System IE fault L2

Ignition lockout after 5 failed attempts

Gas boiler

What it means

Boiler fails to light after 5 ignition attempts and locks out, displaying fault code L2 on the two-digit display.

Likely causes

  1. Failed ignition sequence
  2. Gas supply or ignition fault
  3. Mode knob not in ON position
  4. Timer and Room Thermostat or cylinder thermostat switched off
  5. Radiator valves closed
  6. No voltage from Timer/Room Stat (external wiring fault)
  7. Faulty wiring from terminal strip to PCB

Where to start

  1. Check ignition sequence completed correctly
  2. Restart the boiler per Section 2.25
  3. Observe if boiler repeats ignition sequence

The full answer, free

  • 6 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 36), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Ideal manual for the Logic System IE. Check the model on the data plate before you order parts.