ECA ARCEUS fault F52

Submersion type NTC (DHW outlet temperature sensor) fault

Gas boiler
Free account: 1 more check, the readings and the manual page (page 46). No card needed.See the full F52 answer

What it means

The NTC measures the temperature of the water taken from the domestic water outlet. F52 is associated with malfunction of this sensor, resulting in inability to detect or control DHW temperature correctly.

Likely causes

  1. NTC sensor out of resistance tolerance for ambient/water temperature
  2. Damaged or disconnected NTC electrical connections

Where to start

  1. Disconnect and remove the NTC electrical connections
  2. Measure the resistance between the NTC terminals using a multimeter
  3. Compare measured resistance to the resistance table for the corresponding ambient temperature

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 46), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full F52 fix, readings and manual page. Free.See the full answer

From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.