ECA ARCEUS fault F35
Surface type NTC related fault
Gas boilerFree account: 3 more checks, the readings and the manual page (page 45). No card needed.See the full F35 answer
What it means
Associated with the Surface Type NTC sensor which measures the central heating supply and return water temperatures. Malfunction causes the central heating not to work properly, not heat up, or overheat beyond the set temperature.
Likely causes
- Short-circuit of NTC sensor
- Open-circuit of NTC sensor
- Damaged NTC sensor
- Damaged or disconnected supply line cables
- Surface Type NTC out-of-range resistance / sensor failure
Where to start
- Make sure that the cables of the NTC in the supply line are connected.
- If the cables are plugged in, check the cables end-to-end for damage and that they are plugged into the mainboard terminal.
- If the cables are not damaged, measure the resistance between the terminals of the NTC and check that their values are appropriate.
The full answer, free
- 3 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 45), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F35 fix, readings and manual page. Free.See the full answer
From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.
Other ECA ARCEUS fault codes
- E03Overheat thermostat trip
- E04Associated with contactor malfunction
- E13Too frequent error reset error
- E80Surface type NTC related fault
- F33Surface type NTC related fault
- F34Low voltage error
- F39Outdoor temperature sensor error
- F47Water pressure sensor fault
- F50Solar energy boiler tank temperature sensor error
- F51Solar panel temperature sensor (PT1000) error
- F52Submersion type NTC (DHW outlet temperature sensor) fault