ECA ARCEUS fault F50

Solar energy boiler tank temperature sensor error

Gas boiler
Free account: 1 more check, the readings and the manual page (page 16). No card needed.See the full F50 answer

What it means

Received if the solar energy boiler tank temperature sensor is short-circuit, open-circuit, or damaged. Domestic water and central heating request is stopped. When this error is deleted, normal operation begins.

Likely causes

  1. Short-circuit of boiler tank temperature sensor
  2. Open-circuit of sensor
  3. Damaged sensor
  4. Incorrect P00 parameter setting when boiler/solar tank not in use

Where to start

  1. Reset the error.
  2. If the error persists after reset and boiler or solar energy tank is not used, make sure P00 parameter is not 2, 3 or 4.
  3. If using boiler or solar energy tank, make sure the cabling of the temperature sensor is undamaged and assembled.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 16), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full F50 fix, readings and manual page. Free.See the full answer

From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.