ECA ARCEUS fault E13
Too frequent error reset error
Gas boilerFree account: 20 more checks, the readings and the manual page (page 15). No card needed.See the full E13 answer
What it means
This error is received when 5 errors are reset within 1 hour. Domestic water and central heating requests are stopped. This error can be deleted by simply cutting off the power supply to the motherboard.
Likely causes
- Repeated fault resets occurring within a short time window (5 resets within 1 hour)
- Dead cable to resistor
- Faulty contactor
- Blocked heater installation/plumbing
- Motorised valve not sending water to heater circuit
- Incorrect NTC temperature measurement (supply/return)
- Faulty relay board
- Faulty mainboard
- Dead heating resistor
- Faulty spring in motorised valve supply manifold
- Faulty motorised valve
- Incorrectly installed or faulty flow sensor
- Incorrectly installed or faulty submersion type NTC on hydroblock
Where to start
- Put the device into test mode by pressing and holding K3 and K5 together for 5 seconds; 'FT' will be displayed on the screen.
- Measure the current through the resistor neutral cables using a clamp meter and detect whether there is a dead resistor; if no dead resistor in test mode: check piping connections and make sure central heating valves outside the boiler are turned on.
- If valves are on, remove the motorised valve from the device and make sure its pin is pressed (pin pressed sends water to heater circuit).
The full answer, free
- 20 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 15), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full E13 fix, readings and manual page. Free.See the full answer
From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.
Other ECA ARCEUS fault codes
- E03Overheat thermostat trip
- E04Associated with contactor malfunction
- E80Surface type NTC related fault
- F33Surface type NTC related fault
- F34Low voltage error
- F35Surface type NTC related fault
- F39Outdoor temperature sensor error
- F47Water pressure sensor fault
- F50Solar energy boiler tank temperature sensor error
- F51Solar panel temperature sensor (PT1000) error
- F52Submersion type NTC (DHW outlet temperature sensor) fault