ECA ARCEUS fault E80

Surface type NTC related fault

Gas boiler
Free account: 20 more checks, the readings and the manual page (page 45). No card needed.See the full E80 answer

What it means

Associated with the Surface Type NTC sensor which measures the central heating supply and return water temperatures. Malfunction causes the central heating not to work properly, not heat up, or overheat beyond the set temperature.

Likely causes

  1. Plate exchanger leakage
  2. Scale buildup inside plate exchanger causing inefficient heat transfer
  3. Pump electrical connection fault
  4. Pump motor burned out (short-circuit)
  5. Air purge failure on pump causing installation pressure decrease
  6. Surface Type NTC out-of-range resistance / sensor failure
  7. Dead resistor
  8. Dead cable to resistor
  9. Faulty contactor
  10. Blocked heater installation/plumbing
  11. Motorised valve not sending water to heater circuit
  12. Incorrect NTC temperature measurement (supply/return)
  13. Faulty relay board
  14. Faulty mainboard

Where to start

  1. Visually inspect the plate exchanger for water leakage
  2. Check whether there is a drop in the water pressure in the installation when the domestic water is turned on
  3. Visual inspection of pump electrical connection

The full answer, free

  • 20 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 45), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full E80 fix, readings and manual page. Free.See the full answer

From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.

Other ECA ARCEUS fault codes