Worcester Bosch Greenstar 4000 System fault 2965

Flow temperature too high

Gas boiler

What it means

Flow temperature detected as too high, typically due to lack of water flow.

Likely causes

  1. CH system closed - no water flow
  2. Pump not operating correctly
  3. Air locks in system
  4. Closed isolation valves
  5. Incorrectly set pump rate or pump characteristic map

Where to start

  1. Check for air locks in the system
  2. Check isolation valves
  3. Set the pump rate or pump characteristic map correctly and match to the maximum output

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Worcester Bosch manual for the Greenstar 4000 System. Check the model on the data plate before you order parts.