Worcester Bosch Greenstar 4000 System fault 1074

No signal from flow temperature sensor

Gas boiler

What it means

Service warning (W category) indicating no signal received from the flow temperature sensor.

Likely causes

  1. Disconnected sensor plug
  2. Faulty flow temperature sensor
  3. Harness continuity fault
  4. Faulty PCB

Where to start

  1. Check the flow temperature sensor plug is connected
  2. Check the resistance of the flow temperature sensor
  3. Check the continuity of harness

The full answer, free

  • 6 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 75), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Worcester Bosch manual for the Greenstar 4000 System. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 4000 System fault codes