Worcester Bosch Greenstar 4000 System fault 2916

Boiler electr. system fault

Gas boiler

What it means

Gas valve was detected as open during post-purge.

Likely causes

  1. Gas valve leaking/not sealing
  2. Faulty PCB
  3. Incorrect gas type
  4. Incorrect gas supply pressure
  5. Faulty flue system
  6. Incorrect gas/air ratio
  7. Faulty gas valve
  8. Faulty seals around the burner, internal flue seals or case seals causing abnormal O2/CO2 readings
  9. Flue system integrity failure
  10. Combustion circuit fault

Where to start

  1. Carry out a gas tightness test on the gas valve
  2. Check the voltage to gas valve
  3. Check the gas type