Worcester Bosch Greenstar 2000 fault 364

Solenoid valve EV2 leaking

Gas boiler
Free account: the readings and the manual page (page 67). No card needed.See the full 364 answer

What it means

The boiler has detected that gas valve solenoid EV2 is leaking (passing gas when it should be shut).

Likely causes

  1. Faulty gas valve.
  2. Faulty electrodes or connecting leads.
  3. Faulty appliance electronics.

Where to start

  1. Check the gas valve.
  2. Check the electrodes and connecting leads.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 67), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 364 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.